A longitudinal assessment of the energy and carbon performance of a Passivhaus university building in the UK
Date
2021-12Author
Subject
Metadata
Show full item recordAbstract
There is a limited number of university buildings designed to the Passivhaus standard, therefore, only a few studies have assessed the standard's adoption in this context. This paper aims to address this significant gap by investigating the energy and carbon performance of The Enterprise Centre (TEC), a UK university building, designed and certified to the Passivhaus standard. The building's energy performance was monitored for four years and was predicted by the Passivhaus Planning Package (PHPP) simulations. Results show that TEC met the primary energy requirement of 120 kWh/m2 and space cooling requirement of 15 kWh/m2 during the first four years of operation, as well as the space heating requirement of 15 kWh/m2 during the first two years. TEC had significantly reduced heat losses and heating demand, due to the very high airtightness, 0.21 m3/(m2·h) @50 Pa, and low envelope U-values. The building had significantly lower annual carbon emissions and energy consumption compared to CIBSE TM46 benchmarks and other conventional university buildings. TEC is an excellent building in terms of primary energy, heating consumption, cooling demand, airtightness and carbon emissions. This study bridges the gap on the adoption of the Passivhaus Standard for university buildings to reduce energy consumption and carbon emissions.
Collections
Publisher
Journal
Volume
Pagination
Publisher URL
Number
Recommended, similar items
The following license files are associated with this item: