dc.description.abstract

This article investigates experimentally and numerically the thermal performance of a new type of structural insulated panel (SIP) termed ‘UWall’. The panel core consists of an ad-hoc waffle skeleton of Expanded Polystyrene (EPS), EPS beads mixed with cement mortar (Portland cement type I and recycled concrete aggregate), and two external water-proof cement boards. The experimental programme examined the panels in three Phases. In Phase 1, 200×200×100 mm block specimens were exposed to a temperature of 70°C for 12 hrs. It was found that the new UWall specimens had a better thermal performance (by up to 20%) over other types of walls typically used in house construction in Southeast Asia such as Mon block wall. In Phase 2, five scaled-down house units (1.5×1.5×2.8 m) were built in Thailand. Temperature and relative humidity outside/inside the units were continuously monitored for 7 days during the summer season. It was found that the new UWall has a good thermal resistance, reducing temperatures by up to 4°C compared to mon-block wall material. The house units were subsequently modelled in Abaqus® software, and the modelling approach proved accurate (within 10%) at simulating the thermal performance of the house units. UWall panels were also tested in bending to determine their structural capacity. It was found that the panels can be safely used as load-bearing walls for single-storey houses. Design charts are then proposed and used to design and build a full-scale house in Phase 3. In Phase 3, a 10×7 m full-scale single-storey house was built using the new UWall panels. Based on results from bioclimatic charts, it was found that daytime temperature and humidity in the full-scale house were deemed as uncomfortable. However, if air movement was provided, the house remained within the comfortable zone at all times. New design charts for full-scale houses with UWall are proposed to meet a desired user-comfort level. This study is expected to promote the use of SIPs in house construction in tropical climates, which in turn is envisaged to save energy and make construction more sustainable.

dc.format.extent135568-135568
dc.languageen
dc.publisherElsevier BV
dc.subjectStructural insulated panels
dc.subjectThermal performance
dc.subjectFinite element analysis
dc.subjectBending tests
dc.subjectFull-scale testing
dc.subjectTropical climates
dc.titlePerformance of a novel structural insulated panel in tropical climates: Experimental and numerical studies
dc.typejournal-article
dc.typeArticle
plymouth.volume421
plymouth.publisher-urlhttp://dx.doi.org/10.1016/j.conbuildmat.2024.135568
plymouth.publication-statusPublished
plymouth.journalConstruction and Building Materials
dc.identifier.doi10.1016/j.conbuildmat.2024.135568
plymouth.organisational-group|Plymouth
plymouth.organisational-group|Plymouth|Faculty of Science and Engineering
plymouth.organisational-group|Plymouth|Faculty of Science and Engineering|School of Engineering, Computing and Mathematics
plymouth.organisational-group|Plymouth|REF 2021 Researchers by UoA
plymouth.organisational-group|Plymouth|Users by role
plymouth.organisational-group|Plymouth|Users by role|Current Academic staff
plymouth.organisational-group|Plymouth|REF 2021 Researchers by UoA|UoA12 Engineering
plymouth.organisational-group|Plymouth|REF 2029 Researchers by UoA
plymouth.organisational-group|Plymouth|REF 2029 Researchers by UoA|UoA12 Engineering
dcterms.dateAccepted2024-02-21
dc.date.updated2024-04-26T13:52:31Z
dc.rights.embargodate2025-3-29
dc.identifier.eissn1879-0526
dc.rights.embargoperiod
rioxxterms.versionofrecord10.1016/j.conbuildmat.2024.135568


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record


All items in PEARL are protected by copyright law.
Author manuscripts deposited to comply with open access mandates are made available in accordance with publisher policies. Please cite only the published version using the details provided on the item record or document. In the absence of an open licence (e.g. Creative Commons), permissions for further reuse of content should be sought from the publisher or author.
Theme by 
Atmire NV